LR220 Coating thickness gauge

Гарантия возврата денег, если товар не подойдёт

Описание LR220 Coating thickness gaugeLR220 Coating thickness gauge This instrument is a portable measuring instrument, it can quickly, no damage, precision coating, coating thickness measurement. It can be used in both laboratory and engineering site. Through the use of different probe, can also meet the needs of a variety of measurement. The instrument can be widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and other testing fields. It is a necessary instrument for material protection profession. Function characteristics: Low power consumption: the normal operating current is less than 10mA, and the user can work continuously for over 100 hours. Fast measurement: The measurement speed is fast, even in the statistical state can be quickly measured and timely statistics, without delay; According to The method, both magnetic and eddy current thickness measurement methods are adopted to measure the thickness of non-magnetic and non-conductive cover layer on magnetic metal matrix. Buy a ticket to use eight probes (F400, F1, F1/90°, F10, F3, N400, N1, AND N3). Either a continuous measure (CONTINUE) or a SINGLE measure (SINGLE); Lent works in two ways: DIRECT and group (A-B); Lent has five statistics: MEAN (MAX), minimum (MIN), and number of tests (NO.) , standard deviation (S. EV); The instrument can be calibrated using two methods, and the systematic error of the probe can be corrected using the basic calibration method. Function of Basic calibration indicator: Friendly basic calibration interface, automatically prompts the current calibration point; According to the system, the system can store 768 measurements. Functions to browse data, including viewing all measured data and statistics; According to the System, a single suspicious data is deleted during a measurement, as well as all data in the memory, allowing new measurements to be made. Autonomously set a boundary: a measurement outside the boundary automatically alarms you; According to the System, you communicate with a PC, transferring measured values and statistics to the PC for further processing. Buy a ticket to communicate with the PLC: The measured values and statistics are transmitted to the PLC via RS485. Strong anti-interference ability, long communication distance; Functions of solar energy prompt indicator; The system beeps during operation. The fault prompt function functions automatically, prompting errors through screen display or beeping. Buy a ticket to shut down the device either manually or automatically. Lent ABS packaging, which resists falls and is waterproof, provides safe and reliable protection for the instrument.The main technical indicators: Display error and display repeatabilityMeasuring head typeF400F1F1/90°F3F10The working principle ofMagnetic induction should beMeasuring range (m)0~4000~12500~30000~10000Low resolution (M)0.10.1110In value errorOne point calibration (M)±(3%H+1)±(3%H+5)±(3%H+10)Two point calibration (M)±((1~3)%H+0.7)±((1~3)%H+1)±((1~3)%H+5)±((1~3)%H+10)measuring try articleMinimum radius of curvature (mm)convex11.5flat510Diameter of minimum area (mm)F3F7F7F20F40Critical thickness of matrix (mm)0.20.50.512Measuring head typeN400N1N3The working principle ofVortex flowMeasuring range (m)0~4000~12500~3000Low resolution (M)0.10.10.5In value errorOne point calibration (M)±(3%H+0.7)±(3%H+1.5)±(3%H+5)Two point calibration (M)±[(1~3%H+0.7)±[(1~3)%H+1.5]±((1~3)%H+5)measuring try articleMinimum radius of curvature (mm)convex1.533Diameter of minimum area (mm)F4F5F5Critical thickness of matrix (mm)0.30.30.3Probe selection reference table:coveringsubstrateNon-magnetic coatings such as organic materials (e.g., lacquers, lacquers, enamels, enamels, Plastics and anodizing, etc.)The thickness of overburden shall not exceed 100mThe thickness of overburden layer exceeds 100mMagnetic metals such as iron and steelDiameter of the area to be measured More than 30 mmF400 type probe 0 to 400m F1 type probe 0 ~ 1250mF1 type probe 0 ~ 1250m F3 probe 0 ~ 3mm F10 probe 0 ~ 10mmDiameter of the area to be measured More than 30 mmF400 type probe 0 to 400mF1 type probe 0 ~ 1250m F400 type probe 0 to 400mSuch as copper, aluminum, brass, zinc, tin and other non-ferrous metalsDiameter of the area to be measured More than 10 mmN400 type probe 0 to 400 metersN400 type probe 0 to 400 meters N3 probe 0 ~ 3mmDiameter of the area to be measured More than 10 mmN400 type probe 0 to 400 metersType N1 probe 0 ~ 1250m N400 type probe 0 to 400 meterscoveringsubstrateNon-magnetic non-ferrous metal coating (e.g., chromium, zinc, aluminum, copper, tin, silver, etc.)The thickness of overburden shall not exceed 100mThe thickness of overburden layer exceeds 100mMagnetic metals such as iron and steelDiameter of the area to be measured More than 30 mmF400 type probe 0 to 400mF400 type probe 0 to 400m F1 type probe 0 ~ 1250m F3 probe 0 ~ 3mm F10 probe 0 ~ 10MMMDiameter of the area to be measured More than 30 mmF400 type probe 0 to 400m F1 probe 0 ~ 1250F400 type probe 0 to 400m F1 type probe 0 ~ 1250mSuch as copper, aluminum, brass, zinc, tin and other non-ferrous metalsDiameter of the area to be measured More than 10 mmUsed for chrome plating on copper only N400 probe 0m to 40m--------Diameter of the area to be measured More than 10 mm----------------Standard configuration:The name saysquantityThe host1F1 probe (or N1 probe)1 -Standard piece5 piecesIron matrix (or aluminum matrix)1 pieceProduct packing case1Operating instruction1 thisCommunication cableArticle 1.Communication software1 set ofOptions:The name saysquantityF1/90°1-F4001-F31-F101-N4001-N31-
Свойства товара
  • Warranty: 1YEAR
  • Customized support: OEM, ODM, OBM
  • Place of Origin: Guangdong, China
  • Brand Name: LONROY
  • Model Number: LR220

Комментарии

Популярные объявления